1.
Waste Manag ; 79: 435-442, 2018 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-30343773

RESUMO

The aim of this work was to record the quantities and composition of medical waste (MW) generated by public and private medical histopathology laboratories (HISTOLB) and to provide pertinent waste generation design coefficients (e.g. g/examinee) for those laboratories. This can be a useful coefficient when designing medical waste treatment facilities. The study was conducted on three public and four private HISTOLBs in the city of Thessaloniki (Greece) for a period of 5 months. One sampling week was selected randomly per month. During the study period, the examinees per week were 108 and 90 in the public and private HISTOLBs, respectively. According to the results, 57% of the total MW generated in both the public and private laboratories were toxic waste (TXW), namely the liquid formaldehyde that is used to preserve the tissue. The mixed hazardous waste (MHW) comprised 28% and 24%, respectively, of the total MW, in the public and private facilities, respectively. The infectious waste constituted around 15% of the total MW generated in both types of facilities. Urban type waste was always less than 4% by weight. The total mean MW generated in the public and private laboratories were 208 ±â€¯543 (n = 1614) and 195 ±â€¯512 (n = 1789) g/examinee, respectively. A large variance among the mean MW generation rates of the participating individual laboratories that belonged to the same category was observed. The dominant fraction of the infectious waste was the plastic containers that contained the tissue samples, being around 75% of the total infectious waste, followed by the latex gloves (being around 17% of the infectious waste).


Assuntos
Eliminação de Resíduos de Serviços de Saúde , Resíduos de Serviços de Saúde , Cidades , Grécia , Resíduos Perigosos
2.
Waste Manag ; 61: 539-546, 2017 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-28162901

RESUMO

A study on the generation rate and the composition of solid medical wastes (MW) produced by private medical microbiology laboratories (PMML) was conducted in Greece. The novelty of the work is that no such information exists in the literature for this type of laboratories worldwide. Seven laboratories were selected with capacities that ranged from 8 to 88 examinees per day. The study lasted 6months and daily recording of MW weights was done over 30days during that period. The rates were correlated to the number of examinees, examinations and personnel. Results indicated that on average 35% of the total MW was hazardous (infectious) medical wastes (IFMW). The IFMW generation rates ranged from 11.5 to 32.5g examinee-1 d-1 while an average value from all 7 labs was 19.6±9.6g examinee-1 d-1 or 2.27±1.11g examination-1 d-1. The average urban type medical waste generation rate was 44.2±32.5g examinee-1 d-1. Using basic regression modeling, it was shown that the number of examinees and examinations can be predictors of the IFMW generation, but not of the urban type MW generation. The number of examinations was a better predictor of the MW amounts than the number of examinees. Statistical comparison of the means of the 7PMML was done with standard ANOVA techniques after checking the normality of the data and after doing the appropriate transformations. Based on the results of this work, it is approximated that 580 tonnes of infectious MW are generated annually by the PMML in Greece.


Assuntos
Laboratórios , Resíduos de Serviços de Saúde/análise , Microbiologia , Grécia , Humanos , Laboratórios/organização & administração , Laboratórios/estatística & dados numéricos , Recursos Humanos